request to quote
English
English Chinese Simplified Chinese Traditional French German Portuguese Spanish Russian Japanese Korean Arabic Irish Greek Turkish Italian Danish Romanian Indonesian Czech Afrikaans Swedish Polish Basque Catalan Esperanto Hindi Lao Albanian Amharic Armenian Azerbaijani Belarusian Bengali Bosnian Bulgarian Cebuano Chichewa Corsican Croatian Dutch Estonian Filipino Finnish Frisian Galician Georgian Gujarati Haitian Hausa Hawaiian Hebrew Hmong Hungarian Icelandic Igbo Javanese Kannada Kazakh Khmer Kurdish Kyrgyz Latin Latvian Lithuanian Luxembou.. Macedonian Malagasy Malay Malayalam Maltese Maori Marathi Mongolian Burmese Nepali Norwegian Pashto Persian Punjabi Serbian Sesotho Sinhala Slovak Slovenian Somali Samoan Scots Gaelic Shona Sindhi Sundanese Swahili Tajik Tamil Telugu Thai Ukrainian Urdu Uzbek Vietnamese Welsh Xhosa Yiddish Yoruba Zulu Kinyarwanda Tatar Oriya Turkmen Uyghur Abkhaz Acehnese Acholi Alur Assamese Awadish Aymara Balinese Bambara Bashkir Batak Karo Bataximau Longong Batak Toba Pemba Betawi Bhojpuri Bicol Breton Buryat Cantonese Chuvash Crimean Tatar Sewing Divi Dogra Doumbe Dzongkha Ewe Fijian Fula Ga Ganda (Luganda) Guarani Hakachin Hiligaynon Hunsrück Iloko Pampanga Kiga Kituba Konkani Kryo Kurdish (Sorani) Latgale Ligurian Limburgish Lingala Lombard Luo Maithili Makassar Malay (Jawi) Steppe Mari Meitei (Manipuri) Minan Mizo Ndebele (Southern) Nepali (Newari) Northern Sotho (Sepéti) Nuer Occitan Oromo Pangasinan Papiamento Punjabi (Shamuki) Quechua Romani Rundi Blood Sanskrit Seychellois Creole Shan Sicilian Silesian Swati Tetum Tigrinya Tsonga Tswana Twi (Akan) Yucatec Maya
Leave Your Message

High-Efficiency Stacked Core Transformer from China Factory - Top Suppliers for Industrial Power Supply Solutions

,

Introducing our high-efficiency stacked core transformer, proudly manufactured in China at our state-of-the-art factory. This transformer features a laminated structure made from premium grain-oriented silicon steel sheets, which significantly reduces eddy current and hysteresis losses, achieving energy efficiency levels of up to 98%. Designed for stable operation in a range of temperatures (-20°C to 60°C) and with excellent heat dissipation, it boasts a compact design that allows for flexible installation.

,

Our transformers are customizable to meet various industrial, renewable energy, and commercial needs, with voltage options from 110V to 33kV and power ratings from 5kVA to 5MVA. They are available in a variety of ingress protection ratings (IP23 to IP6to suit diverse applications. As reliable suppliers, we guarantee that our products comply with IEC/ANSI standards, ensuring durability for over 25 years while maintaining low noise levels below 55dB.

,

    Product Specification

    Basic Information
    Item Specification
    Product Model Example: S13-M-100/10 (S=Three-Phase, 13=Efficiency Class, M=Hermetically Sealed, 100=Rated Capacity kVA, 10=HV Rated Voltage kV)
    Rated Capacity(Sn) 50kVA~2500kVA (ONAN: 100% rated capacity; ODAF: 130% rated capacity)
    Phase Three-Phase (Standard) / Single-Phase (Customizable)
    Rated Frequency(fn) 50Hz / 60Hz (±1% tolerance)
    Connection Group Dyn11 (Default) / Yyn0 (Optional, per IEC 60076-1)
    Environmental & Operating Conditions
    Ambient Temperature -25℃~40℃ (-40℃ optional with anti-freeze additive)
    Altitude ≤1000m (5% derating at 1500m, 10% at 3000m)
    Humidity ≤90% @25℃ (no condensation); ≤50% @40℃
    Seismic Resistance GB 50260-2013, 7-degree intensity (0.15g acceleration)
    Protection Class IP20 (Indoor) / IP23 (Outdoor, dust/rain protection)
    Losses & Impedance (Efficiency Core)
    Parameter S13-100/10 Example Test Conditions
    No-Load Loss (Po) ≤170W Rated voltage, rated frequency
    Load Loss (Pk) ≤1050W Rated current, 75℃ reference temp
    Short-Circuit Impedance (Uk%) 4%~6% ±10% tolerance at 75℃
    No-Load Current (Io%) ≤1.2% (≤0.8% for large capacity) Rated voltage
    Efficiency Compliance: GB 20052-2024 Class 2 (S13) / Class 1 (S15, 15-20% lower losses than S13) — IEC 60076-11 IE2/IE3 equivalent for EU markets
    Example S13-250/10 Key Specs
    Item Value
    Rated Capacity 250kVA
    HV/LV Voltage/Current 10kV/14.43A;0.4kV/360.8A
    No-Load/Load Loss ≤320W / ≤2250W
    Short-Circuit Impedance 4.5%
    Core Material 30Q130 Silicon Steel
    Cooling Method ONAN
    Protection Class IP23
    Customization available for special voltages, high-altitude, or explosion-proof requirements. All parameters verified by third-party labs.

    Advantages

    • Superior Energy Efficiency

      Laminated structure with high-grade grain-oriented silicon steel minimizes eddy current and hysteresis losses, achieving up to 98% efficiency—cuts energy consumption and operational costs long-term.

    • 🌡️
      Strong Thermal Stability

      Advanced heat-dissipating design enables reliable work in -20°C to 60°C, avoiding overheating issues.

    • 🔧
      High Customizability

      Flexible voltage (110V-33kV), capacity (5kVA-5MVA), and enclosure (IP23-IP65) options fit industrial, renewable energy, and commercial needs.

    • 🔇
      Durable & Low-Noise

      Compliant with IEC/ANSI standards, it has a 25+ year lifespan and <55dB noise, ensuring long-term stable, quiet operation.

    Product Display

    xiangiqantg (1) xiangiqantg (2)
    xiangiqantg (3) xiangiqantg (4)

    Application

    🏭 Industrial Sector

    Powers heavy machinery (e.g., manufacturing assembly lines, metal processing equipment), industrial control systems, and factory power distribution networks—handles fluctuating loads stably to ensure uninterrupted production.

    ☀️ Renewable Energy Systems

    Integrates with solar photovoltaic (PV) farms and wind power plants, converting unstable renewable energy into grid-compatible electricity for efficient power transmission to the public grid.

    🏢 Commercial & Residential Areas

    Supplies power to commercial buildings (shopping malls, office towers) and residential communities, supporting HVAC systems, lighting, and household/appliance electrical needs with low noise and high efficiency.

    🔌 Power Transmission & Distribution

    Used in medium/high-voltage power grids (e.g., regional substations), stepping up/down voltages to match long-distance transmission and end-user demand, ensuring safe and efficient power supply.

    Frequently Asked Questions

    Q1 What is the difference between S13 and S15 oil-immersed transformers?
    The S13 series complies with GB 20052-2024 Class 2 efficiency standards, while the S15 series meets Class 1 standards with 15–20% lower no-load and load losses compared to S13. S15 is recommended for applications requiring maximum energy savings and long-term cost reduction.
    Q2 Can the transformer be used at high altitudes above 1000m?
    Yes. The standard rating applies at ≤1000m. For higher altitudes, derating is required: approximately 5% at 1500m and 10% at 3000m. Customized high-altitude versions are available upon request to ensure safe and reliable operation.
    Q3 What customization options are available for this transformer?
    We offer a wide range of customization options including voltage ratings (110V–33kV), capacity (5kVA–5MVA), connection groups (Dyn11, Yyn0, etc.), protection class (IP23–IP65), cooling methods (ONAN/ODAF), anti-freeze additives for cold climates, and explosion-proof enclosures for hazardous environments.
    Q4 What international standards does this transformer comply with?
    The transformer complies with GB 20052-2024 (China national efficiency standard), IEC 60076-1 (general requirements), IEC 60076-11, and is equivalent to IE2/IE3 efficiency classes for EU markets. Seismic resistance meets GB 50260-2013 at 7-degree intensity (0.15g acceleration).
    Q5 Is this transformer suitable for solar and wind energy applications?
    Yes. This transformer is well-suited for renewable energy systems including solar photovoltaic (PV) farms and wind power plants. It efficiently converts variable renewable energy output into stable, grid-compatible electricity, supporting reliable power transmission to the public grid.
    Q6 What is the expected service life and noise level of this transformer?
    When operated within rated conditions and maintained properly, the transformer is designed for a service life of 25+ years. The noise level is kept below 55dB, making it suitable for use in noise-sensitive environments such as commercial buildings and residential communities.